Fog in One Cavity
Because a triple unit has two air spaces, fog sometimes shows up in only one of them. Haze that seems to sit closer to the inside or outside lite tells us which part of the seal has let moisture in.

Get your written quote
Heavy glass, matched exactly and set safely
Triple pane windows are built to last, but their sealed glass units can still fog, crack or lose their gas fill. GTS Windows & Doors replaces failed triple pane units in homes and buildings across Kitchener-Waterloo, and we have been working with windows and glass in the region since 1986. In most cases the frame, sash and hardware stay in place and only the glass unit changes, which protects the investment you made in high-performance windows.
A triple pane unit is not simply a thicker double pane. It carries three lites of glass, two gas-filled cavities and often two Low-E coatings, and it weighs about half again as much as a double pane unit of the same size and glass thickness. Replacing one properly means matching the original specification closely and handling the glass with two people and the right lifting gear.
We do this work for owners of newer energy-efficient homes, custom builds and deep energy renovations, and for the builders and property managers who look after them in Kitchener, Waterloo, Cambridge, Guelph and the nearby townships. Triple glass is one part of our wider window repair work, and every job is carried out by a licensed, insured and WSIB covered crew.
Triple pane failures can be subtler than the obvious white fog of an old double pane. Look at the glass on a cold, bright morning, from a few angles, and compare it with the windows beside it.
Because a triple unit has two air spaces, fog sometimes shows up in only one of them. Haze that seems to sit closer to the inside or outside lite tells us which part of the seal has let moisture in.
When both spaces are cloudy, the edge seal has failed around the unit and the insulating gas is gone. The window is now performing well below the rating you paid for.
The middle pane is sealed inside the unit, yet it can still crack from heat stress or a flaw in the glass. A crack you cannot feel from either side is almost always the centre lite, while impact damage to an outer lite is handled much like our broken glass replacement calls.
Frost or heavy condensation on the room-side glass, where there was none before, can mean the unit has lost gas even before fog appears. It is worth a check if one window suddenly behaves differently from its neighbours.
Most of the extra difficulty comes down to size, weight and tight tolerances. Triple pane glass replacement takes more planning than a double pane swap, and it is a poor candidate for a do-it-yourself fix.
On site, we lift the old unit out with suction cups rather than prying it free, and we protect the sash and nearby finishes while the heavy glass is moving. The new unit goes in the same way, with one installer guiding the bottom edge onto the blocks while the other controls the weight.

A mismatched replacement shows. A different Low-E coating can give one window a noticeably different tint or reflection from the rest of the elevation, and the wrong gas fill or spacer changes how warm the glass feels.
Where the original manufacturer is known, we ask for the specification directly. Where it is not, a coating detector tells us which glass surfaces carry Low-E, and we record the rest of the details below before anything is ordered.
| Specification | What we check | Why it matters |
|---|---|---|
| Overall thickness | Measured at the edge and against the glazing pocket | The unit must fit the stops and tape exactly |
| Lite thickness | Usually 3 mm or 4 mm per lite, thicker on large units | Affects weight, strength and cost |
| Low-E coating surfaces | Which faces are coated, often surfaces 2 and 5 | Controls tint, solar gain and winter comfort |
| Gas fill | Argon or krypton in each cavity | Krypton suits narrow cavities and costs more |
| Spacer type and colour | Aluminum, stainless steel or warm-edge foam | Affects edge temperature and appearance |
| Safety glass | Tempered or laminated stamp in a corner | Must be matched where code or the original requires it |
Usually not. A sash built for double glazing has a glazing pocket sized for a much thinner unit, and there is rarely room for the extra lite and cavity. Its hinges, operators or balances are also sized for lighter glass, so a heavier unit can cause sagging and early hardware failure.
Slim triple units with narrow krypton-filled cavities do exist and can fit some sturdier sashes, but the gain over a good Low-E double pane is modest for the cost. If your foggy double pane window simply needs new glass, our double pane glass replacement page covers upgrades that do fit.
If triple glazing is the real goal, the answer is new frames designed to carry it. Our triple pane windows page explains when that upgrade pays off, and we can quote new glass for the failed unit and a full window side by side so you can compare.

Triple pane units usually cost about 30 to 60 percent more than a double pane unit of the same size, mainly because of the extra glass, second coating and gas, and the added handling. Upper-floor windows, shaped units and rush orders add to the price.
The ranges below are typical installed prices in Waterloo Region for 2026, and grouping several units into one order and one visit brings the cost per unit down.
| Unit size | Typical installed price | Notes |
|---|---|---|
| Small (under 6 sq ft) | $375 to $650 | Basement and small casement windows |
| Medium (6 to 15 sq ft) | $550 to $1,000 | Bedroom and living room casements |
| Large (15 to 30 sq ft) | $950 to $2,000 | Picture windows and patio panels, may need extra crew |
| Krypton fill or tempered lites | Add $100 to $400 per unit | Depends on size and specification |
No. The three lites are bonded with spacers and sealant into a single sealed unit, so once any lite or seal fails, the whole unit is replaced. The upside is that the new unit comes with fresh seals, fresh gas and a new glass warranty.
Often it is, because triple pane windows tend to be fairly new and many carry long glass seal warranties. Look for the maker and date on the spacer or in your purchase documents, and check whether labour is included. Our warranty page explains how our own coverage works on the replacement.
Yes. The old unit comes out and the new one goes in during the same visit, so the opening is exposed only briefly, and we use temporary protection while we work. On very cold days sealants and glazing tape are harder to work with, so we aim for a milder day when the schedule allows.
Glass weighs about 1.5 lb per square foot for every 3 mm of thickness, so a triple unit with three 3 mm lites comes to roughly 4.5 lb per square foot, and closer to 6 lb with 4 mm lites. A 3 by 5 foot unit can therefore weigh about 70 to 95 lb. That is why we plan triple pane jobs for two installers with suction lifters.
Send us the rough size of the unit, a photo of the fogged or cracked glass, and a close-up of any stamp on the spacer. We will confirm the specification and quote the replacement.